Dr.Web Server |
You can view and adjust parameters of interaction between Dr.Web and the Server as well as specify settings for the Mobile mode of Dr.Web. The administrator of the anti-virus network can restrict you from adjusting the server connection parameters. If so, the buttons and check boxes are unavailable. In this section: •Settings of the connection to the central protection server •Station connection parameters To go to parameters of interaction between station and server 1.Open Dr.Web menu 2.Make sure Dr.Web operates in administrator mode (the lock at the bottom of the program window is open 3.At the top of the program window, click 4.A product main settings window opens. Select Dr.Web Server at the left of the window. ![]() Figure 26. Station connection settings In the Connection parameters group, you can see: •Connection status—centralized protection server connection status of the station. •Server address—centralized protection server address to which the station is connected. •Station ID—workstation ID for server connection. You can view and manage server connection settings, if the network administrator provides you with the corresponding privileges.
To configure connection to the current server or to a new one, click Change settings. The Connection settings window opens: ![]() Figure 27. Server connection settings In the table, you can see the list of all servers to which the station can connect. You can remove servers from the table and add new ones. The following management elements are available to work with objects in the table: •The •The A valid certificate is required so that the station can connect to the centralized protection server. The certificate can be unique for each specific server or can match several servers. You can add several certificates used for connection to several servers. A valid certificate should be provided by the administrator of the anti-virus network. By default, the certificate that was used during the installation process is specified, unless the administrator has not changed the encryption keys on the server. If the keys have been changed, the latest certificate from the list of generated certificates is shown. To view the list of available certificates or add another one, click the List of certificates link. To add a new certificate, click To delete unused certificate, click To edit the station connection parameters 1.In the Station connection parameters window, specify the station ID and the password used for server connection. This information is provided by the server administrator. 2.Click OK to save changes. To reset connection parameters and connect to the centralized protection server as a newbie 1.In the Station connection parameters window, click Reset the parameters and connect as a newbie. 2.In the open window, confirm that you want to reset the connection parameters and connect as a newbie. Please note that this action cannot be undone. 3.Dr.Web receives new station ID and password after the station registration is confirmed on the centralized protection server. The new station ID and password will be used for server connection. To open advanced settings, click the Advanced settings link in the Dr.Web Server window (see Figure Station connection settings). You can choose the following options in the Advanced settings group: •Synchronize system time with the server time—synchronize system time on your computer with the time on the centralized protection server. In this mode, Dr.Web periodically sets the time on you computer in accordance with the server time. •Use Mobile mode when there is no connection with the server—keep virus databases up-to-date. If your computer is disconnected from the centralized protection server for a long time, we recommend enabling the Mobile mode of Dr.Web operation in order to receive updates from the Doctor Web update servers. For that purpose, select the Use Mobile mode when there is no connection with the server check box.
In the Mobile mode, Dr.Web attempts to connect to the centralized protection server. After three unsuccessful attempts, it performs an update of the virus databases from Doctor Web update servers. Attempts to establish server connection are performed with an interval of about one minute. To configure Mobile mode settings 1.Click Configure button. The Mobile mode window opens. 2.From the Receive updates drop-down list, select the frequency of checking updates on the Doctor Web update servers.
3.To use proxy server, select the corresponding check box. The following fields will become active:
4.When you finish the adjustments, click OK to save changes or Cancel to exit the window without saving the changes.
All changes specified for the workstation on the server take effect only after the Mobile mode is disabled and connection between Dr.Web and the centralized protection server is reestablished. |